Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Orthopaedics ; (12): 1350-1360, 2021.
Article in Chinese | WPRIM | ID: wpr-910722

ABSTRACT

Objective:To analyze the predictive value of enhanced MRI in the outcome of prolapsed and sequestrated lumbar disc herniation through a retrospective analysis.Methods:A retrospective analysis of the data of 64 patients with prolapsed and sequestrated lumbar disc herniation from January 2015 to December 2018, including 38 males and 26 females; age 35.72±12.44 years (range, 22-64 years) ; 43 cases of prolapsed type, 21 cases of sequestrated type. Conservative treatment was the first choice for all patients, in case of surgical indications during the treatment, percutaneous endoscopic lumbar discectomy or fenestration discectomy will be performed. Enhanced MRI was performed at the first and last inspections, the volume of the protrusion, the thickness of rim enhancement (Tr), and the extent of rim enhancement (Er) were measured and calculated at the same time. According to the ring around the protrusion, the size of the rim-enhancement area was divided into type I-III; then compared the relationship between the rim-enhancement signal differentiation and the resorption rate of protrusions, and the correlation between Tr, Er values and the resorption rate of protrusions during the initial inspection.Results:Among the 64 patients, 42 patients completed conservative treatment, and 22 received surgical treatment. According to the rim-enhancement signal differentiation, 23 cases were treated conservatively for type I, 3 cases were treated by surgery; 16 cases were treated for type II conservatively, 7 cases were treated by surgery; 3 cases were treated for type III conservatively, and 12 cases were treated by surgery. All patients were followed up for 12 to 34 months. Among 42 conservatively treated patients, The volume of the protrusion before treatment was 2 645.67±690.86 mm 3, and the volume of the protrusion after treatment was 842.76±573.35 mm 3. The volume of protrusions before and after treatment was statistical significance ( t=11.897, P<0.001), Tr was 1.38±0.83 mm, and Er was 73.08%±34.39%, the resorption rate of protrusions was 65.10%±24.50%, and 39 cases (92.86%, 39/42) reached the standard for protrusion resorption (resorption rate ≥30%); 23 cases of type I , the resorption rate was 76.54%±18.62%; 16 cases of type II had an resorption rate of 56.81%±21.44%; 3 cases of type III had an resorption rate of 21.58%±12.19%. The resorption rate of type III were compared by single factor analysis of variance, and the difference was statistically significant ( F=12.885, P<0.001); 32 cases of both type I and II (82.05%, 32/39) had significant resorption (resorption rate ≥50%), and no case of type Ⅲ had significant resorption, comparing with type I and II, the difference was statistically significant ( P=0.010); Tr was positively correlated with resorption rate ( r=0.569, P<0.001), Er was positively correlated with resorption rate ( r=0.677, P<0.001). Conclusion:Under close clinical observation, parts of the prolapsed or sequestrated lumbar disc herniations can be conservatively treated, and the herniated disc can be resorption in many people and the clinical symptoms were alleviated. Rim-enhancement signal differentiation by enhanced MR has a better predictive value for the outcome of the herniation, type I is more prone to resorption, preferred conservative treatment, type Ⅲ is not easy to resorption, preferred surgery treatment, and the higher thickness of rim enhancement, the greater extend the rim-enhancement, the more prone to resorption phenomenon.

2.
Journal of Modern Laboratory Medicine ; (4): 22-25, 2016.
Article in Chinese | WPRIM | ID: wpr-493768

ABSTRACT

Objective To establish the method of identifying MRSA with Taqman-fluorescence quantitative PCR basing on mecA/nuc/fem B three gene combined detecting.Methods Taking the coagulase positive MRSA,which isolated from the clinical samples and confirmed by VITEK 2 compact microbial analyzer,as the research obj ect,designed mecA/nuc/fem B specific PCR primers and Taqman fluorescent probe by bio-software PrimerPremier 5 and Designer Beacon 7,FAM,HEX and ROX markers were used to label the fluorescent probe at 5’,and the end of 3’was labeled with BHQ1,detected by fluo-rescence quantitative PCR instrment.Results ①1 g/dl gel electrophoresis results showed that the primer’s specificity of mec A/nuc/fem B were good,and molecular weight of the amplification band consistent with the expected molecular weight and no non-specific amplification band.②Three genes were obtained specific amplification in a single tube single channel and single tube multiple channel detection in PCR,and the three gene amplification effect in a single tube single tube single chan-nel and multichannel PCR similar.Conclusion Successfully established a method of multi channel Taqman-probe fluores-cence quantitative PCR identification of MRSA,mec A/nuc/fem B combined detection can effectively differentiate coagulase negative and positive MRSA,improve the accuracy of identification.

3.
International Journal of Laboratory Medicine ; (12): 743-744, 2015.
Article in Chinese | WPRIM | ID: wpr-460702

ABSTRACT

Objective To apply the six sigma(6σ) quality management method to quantitatively analyze the quality control data of the detection items from different groups and conduct the comparison for analyzing the evaluation performance and improving the laboratory quality .Methods The data of the internal quality control and the external quality assessment were collected from35 de‐tection items in the clinical chemistry laboratory group and the hematology laboratory group during 2013 ,the σ value of every item was calculated and the analytical performance of the detection item was analyzed .Results Among 23 clinical detection items in the biochemistry group ,there were 10 items of σ ≥ 6 ,6 items of 5 ≤ σ < 6 ,3 items of 4 ≤ σ < 5 ,3 items of 3 ≤ σ < 4 and 1 item of σ < 3 , the average σ was 5 .962 .Among 12 clinical detection items in the hematology group ,there were 8 items of σ ≥ 6 ,2 items of 5 ≤ σ <6 ,2 items of 4 ≤ σ < 5 ,the average σ value was 7 .38 .The detection items in which the analytic performance did not reach 6σ in the biochemistry group accounted for 37% of the total items ,which in the hematology group accounted for 11% ,the differences in theσ quality level of detection items between the biochemistry group and the hematology group had statistical significance(P< 0 .05) , the differences in the σ quality level of detection items between the matched reagent and the non‐matched reagent had statistical sig‐nificance (P< 0 .05) .Conclusion The 6σ quality management method can be used used in the quality evaluation of clinical detection items and can be widely used in the quality management of clinical laboratory .

SELECTION OF CITATIONS
SEARCH DETAIL